Call 01543 750008

Root cause analysis methods for maintenance teams

Five whys, fishbones, fault trees and timelines. Which root cause method fits which breakdown, and how to pick one without turning it into a project.

SiteSOS team · · 5 min read

The gearbox on the main conveyor has failed for the second time since Easter. Same output bearing. The first time, the fitters swapped the gearbox and wrote "bearing failed" on the job sheet. This time the production manager wants to know why.

So someone books a room, prints a fishbone template off the internet and gets six people round a table. Two hours later the whiteboard is full. Man, machine, method, materials. Every branch has something on it. Nobody can say which one did it.

The method wasn't wrong. It was the wrong method for that fault, run by the wrong people, at the wrong time.

HSE won't pick one for you

HSE's guide to investigating incidents, HSG245, is written for health and safety events. Its thinking carries straight over to breakdowns. It says there are many tools for finding root causes, and HSE "does not endorse any one method". These techniques are "simply tools, not an end in themselves" (HSG245).

It also says a simple approach is fine for most jobs, as long as it's methodical and has "full employee participation". The heavy techniques are for large, complex or technical investigations.

That's the right starting point. Pick the lightest method that will find the cause. Most breakdowns don't need a two-hour session. A few do.

Know what you're looking for

HSG245 splits causes into three layers. Breakdowns fit them well.

The immediate cause is "the most obvious reason" it happened. The bearing failed. The underlying cause is the less obvious system reason. The bearing ran short of oil because the level check was dropped from the PPM. The root cause is the failing that everything else springs from. The guide says root causes are "generally management, planning or organisational failings" (HSG245). Nobody reviewed the PPM when the conveyor speed went up.

If your write-up stops at "bearing failed", you've found the immediate cause and nothing else. That's why it fails again.

Five whys: the everyday tool

For a single fault with one clear chain, start here. Ask why it happened, then why that happened, and keep going. HSG245 uses the same idea.

It's quick. Two people at the machine can do it in twenty minutes. It falls down when there's more than one cause, because it follows one branch and ignores the rest. We cover how to run one without anyone getting defensive in five whys on the shop floor.

Timeline: when nobody agrees what happened

Some faults turn into an argument about the order of events. Days says it was fine at handover. Nights says it was already making a noise.

So build the timeline first. Pull the HMI alarm history, the PLC logs, the shift notes and the CMMS. Line them up by time. HSG245 asks the analysis to set out the sequence of events and conditions that led up to the event. Do that before anyone offers a theory. Half the time the timeline shows the cause by itself. The pressure dropped two minutes before the first trip, not after.

Fishbone: when there could be lots of causes

The fishbone is good for faults with many possible causes and no obvious lead. Quality defects, intermittent jams, a machine that's "never been right since the move".

The trick is to treat it as a list of things to check, not a list of answers. Every branch becomes a test. Measure the air pressure. Check the batch of film. Watch the operator change a reel. Cross off what's ruled out. If you finish the session with a full whiteboard and no tests booked, you've wasted the morning.

Fault tree: for the ones that matter

A fault tree works backwards from the failure. What has to happen for this to occur? Then what has to happen for each of those? It shows where one failure is enough and where it takes two at once.

It's slow, and it needs someone who knows the machine and its controls well. Save it for safety-related failures, high-cost stoppages and faults that have beaten the other methods. On a drive or a safety circuit, the person drawing the tree needs to read the drawings. Our half-split fault-finding piece covers the same logic for live fault-finding.

Which faults get the full treatment

You can't run a deep investigation on every breakdown. HSG245 says the level of investigation should depend on the potential consequences and how likely it is to happen again. What happened this time is only part of it. It also says a run of similar events may be worth investigating, even if each one alone isn't (HSG245).

So here's our rule of thumb. One-off fault, low cost: a line in the log. Second time on the same part: five whys. Third time, or anything that touches a safety function: timeline and a proper session.

The right people in the room

HSG245 says the team needs people who know the work, plus people with investigation skills. It also says the team should be led by, or report to, someone with authority to act on what they find (HSG245).

On a maintenance team that means the fitter who did the repair, the operator who was there, and a manager who can sign off spend. It also means the right trade. If the repeat fault is in the drive and nobody in the room understands drives, the session will land on the mechanical parts because that's what people know.

This is where repeat faults get expensive. A gearbox swap every four months, plus the downtime each time, soon costs more than a day of the right specialist. If you don't have the skill in-house, bring it in for the investigation, not only for the next breakdown. See the fault that keeps coming back for how to fit that into a busy shift.

Finish the job

The guide makes a point every maintenance manager should pin up. The last steps, putting the action plan in place and checking it's done, are "often overlooked". Without them, "in the long term nothing will change" (HSG245).

Every root cause session should end with actions, owners and dates in the CMMS. Then put a reminder on the machine record to check, three months on, whether the fault came back.

What to do on Monday

  1. Pull your three most repeated faults from last quarter's breakdown log.
  2. Pick one and build a timeline from the alarm history before anyone offers a theory.
  3. Agree your rule for which faults get five whys and which get a full session.
  4. Check the actions from your last root cause session. Are they done?

Get the right engineer on the repeat fault

Running a site?

SiteSOS sends vetted maintenance engineers to your site for breakdowns and shift cover. You see the hourly rates first, and you approve the timesheet from your phone when the job's done.

Get engineers on call

Are you an engineer?

Breakdowns and shift cover near you, paid by the job. Offers show where, what, how far and the least you'll earn, and turning one down never counts against you.

Join as an engineer

Read next

More on maintenance strategy