Call 01543 750008

Hydraulic cylinder drift: finding where the oil is going

A ram that creeps when it should hold is leaking somewhere. How to work out if it's the seal, the valve or the oil, without anyone standing under the load.

SiteSOS team · · 5 min read

It's the start of nights. The lift table at the end of the packing line was left up at the top of its stroke on days. Now it's a hand's width lower than it was. Nobody touched it.

On the press next door, the platen creeps down a few millimetres every time the operator pauses. The tooling setter has started putting a block of wood under it "just in case".

That block of wood is the most honest thing on the shop floor. Everyone knows the cylinder can't be trusted to hold. A drifting cylinder means oil is getting past something. Until you know what, treat every raised load as if it could come down.

Prop it first

Before anyone diagnoses anything, make the load safe. A cylinder holding a load up is stored energy, and isolating the pump doesn't remove it.

PUWER's code of practice says potential energy can't be isolated. There should still be a way to stop it hurting people, "by shielding, barriers or restraint" (L22, paragraph 199). HSE's design advice calls for check valves and mechanical supports that are easy to use from outside the danger area (HSE, fluid injection).

So use the props, pins or safety blocks the machine came with. If it didn't come with any, lower the load to its stops before anyone goes near it. Never put a hand, a head or a body under a raised load that's only held by oil. The block of wood isn't a prop either. Proper supports are rated for the load and designed to fit.

Then isolate and lock off as you would for any job. Our post on safe isolation covers the steps, including stored energy.

Where the oil goes

There are four usual places, and the fix is different for each:

  • Past the piston seal, inside the cylinder. Oil goes from one side of the piston to the other. You won't see it from outside.
  • Through the valve. A directional valve with a worn spool leaks across from the cylinder port to tank. Spool valves are never leak-free, so some drift through them is normal. A pilot operated check or counterbalance valve should stop that, unless it's dirty, worn or set wrong.
  • Out of the system. A leaking fitting, hose or rod seal. This one you can usually see. Our guide to hydraulic leaks covers how to find it safely.
  • Into the oil itself. Oil shrinks as it cools. A cylinder set at the end of a hot shift can drop a little overnight with nothing wrong at all.

Ask the right questions

Before you strip anything, get the history. These questions save hours:

  • Does it drift under load only, or empty as well? A seal that's only just failing may hold an empty table and drift with a full one.
  • Does it drift in one direction or both? A rod that creeps out on its own, as well as in, can point to the valve.
  • Is it worse when the oil is hot? Thin, hot oil gets past worn parts more easily. Our post on hydraulic oil running hot explains why.
  • Did it start after a repair? A new valve fitted the wrong way round, a counterbalance valve wound back, or a pilot line connected to the wrong port can all cause it.
  • Is the cylinder hot? A cylinder that's warmer than its neighbours is often bypassing inside.

Split the cylinder from the valve

The test that settles it is separating the cylinder from the valve. If the cylinder holds with the valve out of the way, the valve is leaking. If it still drifts, the leak is in the cylinder.

How you do that depends on the circuit. It might mean fitting a gauge to each side of the cylinder, blanking the lines, or using isolating valves already fitted. On a single acting ram it's often simpler. What matters is that the load is mechanically supported or fully lowered while anyone opens a line. Trapped pressure between a closed valve and a cylinder can be high, and it doesn't show on the main gauge.

HSE's safety alert on injection injury says checking a replacement should be regarded as a pressure test, with the right precautions (HSE safety alert). The same thinking applies when you open lines on a system that might still hold pressure. Crack fittings slowly, wrapped in a rag, with your face out of line.

If the test is a job nobody on shift has done before, it's a job to plan rather than try at 3am.

Fix the cause, not the symptom

Once you know where the oil is going, fix it properly.

  • A piston seal. Reseal the cylinder, and look at why it went. A scored bore, dirty oil or a side load on the rod will kill the new seals too.
  • A spool valve. Some drift through a spool is normal, so the real question is whether the circuit should have a load holding valve. If it should and doesn't, that's a design point to raise with the machine builder.
  • A check or counterbalance valve. Clean it, check it, or replace it, and set it to the figure on the schematic. Don't wind it until the drift stops.

Where hose failure could let a load drop, HSE advises hose burst valves if there's a risk of injury from component failure (HSE, fluid injection). If the lift table or press doesn't have one, ask why.

Some of this kit is lifting equipment too. The LOLER code of practice lists vehicle inspection hoists and scissor lifts as examples (L113, paragraph 28). If yours is covered, a cylinder that won't hold a load is something to tell the examiner about. Our post on LOLER thorough examinations covers when an exam is due after a repair.

Who should do it

Resealing a cylinder is fitter's work. Working out whether the drift is the cylinder, the valve or the circuit is a hydraulics job. It needs someone who can read the schematic and knows what a counterbalance valve is meant to do.

Here's our view. Drift is a fault sites live with for months, propped with wood, because the machine still runs. Then a seal lets go completely on a busy shift. Get the right person in while it's still creeping, not when it drops.

What to do on Monday

  1. Walk every machine with a raised load held by hydraulics. Check the proper props or blocks are there and used.
  2. Take the wooden blocks away and replace them with rated supports.
  3. List every cylinder that drifts, and put a date on finding the cause for each.
  4. Check your critical lift tables and presses for load holding or hose burst valves.

Paragraph numbers refer to L22, fourth edition (2014, amended 2018), and L113, second edition (2014, amended 2018).

Get the drift found before someone's under it

Running a site?

SiteSOS sends vetted maintenance engineers to your site for breakdowns and shift cover. You see the hourly rates first, and you approve the timesheet from your phone when the job's done.

Get engineers on call

Are you an engineer?

Breakdowns and shift cover near you, paid by the job. Offers show where, what, how far and the least you'll earn, and turning one down never counts against you.

Join as an engineer