Call 01543 750008

Hydraulic pump noise and cavitation

A pump that whines or rattles like gravel is starving or sucking air. How to tell which, what to check first, and why a new pump won't fix it.

SiteSOS team · · 5 min read

It's Monday, 6am. The press has been off all weekend. Someone starts the power pack and it screams. A high whine with a rattle under it, like there's gravel going through the pump. After twenty minutes it settles down a bit, and the press runs.

By Wednesday it's screaming all the time. By Friday the pressure won't hold and the press is slow on every stroke.

That noise is the pump telling you it can't get oil. Either it's starving on the inlet, or it's pulling air in with the oil. Both will wreck it. Change the pump without finding out which, and the new one goes the same way.

Cavitation or air?

They sound alike, but they're different faults with different fixes.

Cavitation is starvation. The pump can't fill on the suction side, so the pressure there drops far enough for vapour bubbles to form. When those bubbles hit the pressure side, they collapse hard against the metal. You get a steady, high whine, often with that gravel rattle. It's worst on a cold start, when the oil is thick and hard to pull through the strainer.

Aeration is air getting in. It sounds more erratic: knocking, banging, a noise that comes and goes. The oil in the tank looks milky or has foam on top. Cylinders go spongy and jerk instead of moving smoothly.

So before you pick up a spanner, look in the tank and listen for a minute. Steady whine on a cold start points to the inlet. Foam and a noise that wanders points to air.

Start at the tank

Most of the causes we find are cheap, and most of them are at the tank end. Roughly in the order we'd check them:

  • Oil level. Low oil means the suction can pull a vortex and suck air. Check it with the cylinders in the position the manual says, usually retracted.
  • The suction strainer. A blocked strainer starves the pump, and it gets worse as the oil thickens on a cold morning. If nobody can remember when it was last cleaned, start here.
  • The suction valve. Many power packs have an isolating valve on the suction line. After a pump change, someone leaves it part shut. Check it's fully open, and that the handle hasn't been knocked.
  • The tank breather. If it's blocked, the tank can pull a slight vacuum as the level drops. That makes the pump work harder to fill.
  • The return line. If it ends above the oil level, the returning oil splashes in and whips air into it. The return should finish below the lowest oil level.
  • The wrong oil. Too thick for the job or the temperature, and the pump can't pull it in. Check what's in the tank against the manual, not against the drum in the stores.

Then the suction line

If the tank end is good, walk the suction line from the tank to the pump.

The suction side sits below atmospheric pressure when the pump is running. A loose clamp or a cracked fitting there won't drip oil. It draws air in instead, so you won't see it. Check every clamp and joint. Look for a suction hose that's gone soft and collapses when the pump runs.

The pump shaft seal can do the same thing. A worn seal on some pumps lets air in, not oil out. If the pump has a case drain, check the line isn't kinked or blocked. A blocked case drain puts pressure on the shaft seal and can blow it.

Is it even the pump?

Not every noise is a pump fault. Rule out these before you condemn it:

  • The coupling. A worn spider or a misaligned coupling gives a knock that follows motor speed, not system pressure. Look at it with the guard off and the pack isolated.
  • The relief valve. A relief valve that's chattering can squeal like a pump. If the noise changes when the system hits pressure, the relief valve is a suspect.
  • Motor speed. If the motor was changed recently, check the speed matches the old one. A pump driven faster than its rating can cavitate on a perfectly good suction line.
  • Bearing noise. A rumble that's there at any pressure may be the motor or pump bearings. Our guide to bearing noise and heat covers that.

A stethoscope or an ultrasound gun helps you work out where the noise really comes from. Our piece on ultrasound for leaks and bearings explains how the kit works.

Keep your hands off it

The pump is noisy, the press is slow, and someone wants to feel along the pipes to find the problem. Don't let them.

HSE's safety alert on injection injury warns that people can come into contact with a fluid jet during inspection or maintenance "prompted by a reduction in performance of the equipment" (HSE safety alert). That's exactly this job. HSE also lists searching for leaks with bare hands as a common error (HSE, fluid injection). Use card, and release the pressure before you open anything. Our post on the first ten minutes of a hydraulic failure covers what to do if someone gets hit.

Don't just change the pump

Here's what we see most. The pump is noisy, so the pump gets changed. The new one is quiet for a week, then starts screaming. The strainer was the problem all along, and now there are two dead pumps.

A cavitating pump also sheds metal. That metal goes round the system and into the valves. If the pump has been noisy for weeks, change the filters after the repair, and think about an oil sample. Our post on oil analysis for gearboxes and hydraulics explains what a sample can tell you.

PUWER's code of practice says maintenance should follow the manufacturer's recommendations, "for example periodic lubrication, replacement and adjustment of parts" (L22, paragraph 74). Strainer cleaning and filter changes are on that list for almost every power pack. If they're not on your PPM, add them.

Who should find it

A good fitter can work through the tank and suction checks. Diagnosing a worn pump, a sticking relief valve or a pump that's cavitating on a sound suction line is another job. It takes someone who can read the hydraulic schematic and put gauges on the system safely.

If that person isn't on your shift, get one in before the pump fails outright. A noisy pump gives you days. A seized one stops the line until a new pump arrives, and then you still have to find the cause. Work out what an hour of that costs with our guide to the cost of downtime.

What to do on Monday

  1. Find out when the suction strainer was last cleaned on each hydraulic power pack.
  2. Check every suction isolating valve is fully open, and lock or tie the handle open.
  3. Brief your shifts: no hands on hoses or pipes when looking for a fault.
  4. Put strainer and filter changes on the PPM for every power pack, from the manual.

Paragraph numbers refer to L22, fourth edition (2014, amended 2018).

Get a hydraulics engineer on it before the pump lets go

Running a site?

SiteSOS sends vetted maintenance engineers to your site for breakdowns and shift cover. You see the hourly rates first, and you approve the timesheet from your phone when the job's done.

Get engineers on call

Are you an engineer?

Breakdowns and shift cover near you, paid by the job. Offers show where, what, how far and the least you'll earn, and turning one down never counts against you.

Join as an engineer